| Standard | ||||
Item | Type | Q'ty | Remarks |
|
| Pump | Air vent valve at casing top | 1 | ||
| Flushing pipe & joint (for mechanical seal) | 2 sets | |||
| Grease nipple | pin type | 2 | ||
| Gauge root valve | 2 | |||
| Gauge board with press. gauges | 1 set | |||
| Safety device | Pump over disch. press. trip | elect. | 1 | |
| Pump casing high temp. alarm & trip | capillary | 1 | ||
| Pump BRG high temp. alarm & trip | capillary | 2 | ||
| Stuffing box seal high temp. alarm & trip | capillary | 1 | ||
| Option (if required) | ||||
| Mech. & Air type device | Pump suc. & disch. press. remote indication (2 gauges) | air | 1 set | |
| Relay box for temp. indicator at driver side | elect. | 1 | ||
| Pump mech. seal steam cleaning device | steam | 1 set | ||
| I.M. shaft upper BRG high temp. alarm & trip | capillary | 1 | ||
| COW main line press. remote indication (1 gauge) | air | 1 set/ship | ||
| Main cargo line press. remote indication (2 gauges) | air | 1 set/ship | ||
| Main cargo line press. remote indication (3 gauges) | air | 1 set/ship | ||
| Emerg. trip device at pump room | air | 1 | LR |
|
| Emerg. trip device at manifold(2), pump room entrance(1) | air | 1 set/ship | ||
| Universal joint for floating shaft | 1 | |||
| Elec. Intrinsically safe system (EISS) | Pump suc. & disch. press. remote indication (2 gauges) | elect.i | 1 set | |
| Remote temp. indication device for pump casing, pump BRG & stuffing box seal | elect.i | 1 set | OCIMF |
|
| Remote temp. indication device & CCR indication for pump casing, pump BRG & stuffing box seal | elect.i | 1 set | OCIMF |
|
| Pump vibration monitoring device | elect.i | 1 set | OCIMF |
|
| Pump mech. seal leakage alarm device | elect.i | 1 set | OCIMF |
|
| I.M. shaft upper BRG high temp. alarm & trip | elect.i | 1 | ||
| COW main line press. remote indication (1 gauge) | elect.i | 1 set/ship | ||
| Main cargo line press. remote indication (2 gauges) | elect.i | 1 set/ship | ||
| Main cargo line press. remote indication (3gauges) | elect.i | 1 set/ship | ||
| Emerg. trip device at pump room | elect.i | 1 | LR |
|
| Emerg. trip device at manifold(2), pump room entrance(1) | elect.i | 1 set/ship | ||
| Note 1. | elect.i : Electric intrinsically safe device (included sensor, barrier, indicator etc.) |
| Mechanical seal | 1 pump |
| Coupling bolt & nut | 1 pump |
| Mouth ring | 1 pump |
| Ball bearing | 1 pump |
| Line bearing | 1 pump |
| Packing ring | 1 pump |
| Stuffing box seal | 1 pump |
| Complete set of rotating element | 1 pump (if required) |